Murata · Japan · SIP thick film

Murata MHR0319SA Series High Voltage Resistor Replacement

MHR0319SA is the substrate series, not a complete part number: the 20.2 mm long, 5 mm high member of the Murata MHR SIP line, 1 W, 8 kV single use and 14 kV once molded. HVC builds the same outline as a thick film plate with a cut body, so the lead pitch and the seated height stay where the PCB expects them.

SIP thick film high voltage resistor replacing Murata MHR0319SA

MHR0319SA cross reference

ItemMurata MHR0319SAHVC alternative
Body (L × H)20.2 × 5 mm5.0 mm high, cut to 20.2 mm long, cut to 20.2 mm
Lead pitch17.78 mmSame, set on the drawing
Rated power1 W1 W
Rated voltage8 kV single / 14 kV molded7 kV air, continuous
Resistance1–2000 MΩ, nine stepsAny value in range
ModelMHR0319SAHVRGHP5.20

Same outline. Murata figures are the catalogue values for this body. HVC ratings are continuous values in air. Confirm the medium and the duty in the RFQ.

Why buyers arrive with a MHR0319SA number

The usual case is not a purchase order. It is a repair, a drawing carried over from an older machine, or a design inherited from a supplier that no longer supports it. The number is the only firm fact available, and the question behind it is simply whether the part can still be obtained at the printed outline.

That is a different question from price. Murata builds MHR0319SA in nine resistance steps; anything between the steps, anything above 1 W, or anything above 8 kV in air has no catalogue answer at all, and that is where a cut-to-outline plate replaces the original rather than competing with it.

Reading the MHR0319SA voltage figure

Two columns sit behind the headline number: 8 kV for single use and 14 kV for molded use. The gap is the potting, not the resistor. A substitute quoted at the molded figure without the molding is not the same part, so state the medium and the duty in the enquiry and the quotation will match it.

MHR0319SA ordering codes

코드는 MHR0319SA plus a three digit resistance code, a tolerance letter and a two digit individual specification: 70 for single use, 20 for molded use. Standard resistance steps are 10, 15, 20, 25, 30, 40, 50, 68 and 80; the three digit code carries two significant figures and the number of zeros that follow.

ResistanceCodeOrdering number (±1%, single use)
1 MΩ105MHR0319SA105F70
1.5 MΩ155MHR0319SA155F70
2 MΩ205MHR0319SA205F70
2.5 MΩ255MHR0319SA255F70
3 MΩ305MHR0319SA305F70
4 MΩ405MHR0319SA405F70
5 MΩ505MHR0319SA505F70
6.8 MΩ685MHR0319SA685F70
8 MΩ805MHR0319SA805F70
10 MΩ106MHR0319SA106F70
15 MΩ156MHR0319SA156F70
20 MΩ206MHR0319SA206F70
25 MΩ256MHR0319SA256F70
30 MΩ306MHR0319SA306F70
40 MΩ406MHR0319SA406F70
50 MΩ506MHR0319SA506F70
68 MΩ686MHR0319SA686F70
80 MΩ806MHR0319SA806F70
100 MΩ107MHR0319SA107F70
150 MΩ157MHR0319SA157F70
200 MΩ207MHR0319SA207F70
250 MΩ257MHR0319SA257F70
300 MΩ307MHR0319SA307F70
400 MΩ407MHR0319SA407F70
500 MΩ507MHR0319SA507F70
680 MΩ687MHR0319SA687F70
800 MΩ807MHR0319SA807F70
1000 MΩ (1 GΩ)108MHR0319SA108F70

Tolerance letters: D ±0.5%, F ±1%, G ±2%, J ±5%, K ±10%, M ±20%. Replace F with the tolerance you need, and 70 과 20 for the molded specification. HVC builds any value in the range to the same outline.

MHR0319SA replacement FAQ

Do I need to have bought the MHR0319SA before?

No. Most enquiries arrive with a part number and no purchase history - a repair, a legacy drawing, or a design inherited from another team. Send the number and the quantity; HVC quotes a substitute against the printed outline rather than asking for an order history.

Is the MHR0319SA body still available?

HVC supplies the HVRGHP5.20 plate cut to 20.2 mm, 5 mm high, with the lead pitch set to 17.78 mm. This size is held as a catalogue outline.

What does the voltage figure actually mean?

Murata lists two columns: 8 kV single use and 14 kV molded use. The higher number depends on the part being potted. HVC quotes a continuous working voltage in air, so compare air with air and ask for the medium on any substitute you are offered.

Can HVC supply values outside the 1 to 2000 MΩ range?

Yes. Murata builds nine resistance steps; HVC builds any value in the range, which is the usual reason a buyer with a MHR0319SA drawing cannot simply re-order the original.

Other MHR substrate sizes

이 페이지에서 사용된 HVC 제품군: GHP flat-style plate resistor.

기술 견적 / 6시간 이내 답변

사양을 보내주시면 저희가 맞춰드리겠습니다.

부품 번호, 도면, 데이터시트 또는 BOM을 보내주십시오. HVC 영업 및 엔지니어링 팀에서 적절한 제품 개발 방안과 견적을 제시해 드리겠습니다.

기술 견적 요청