고전압 커패시터

Quote within 6 hours · radial-lead ceramic typically 3–4 weeks · fast screw-terminal ranges about 1 month.

HVC manufactures high voltage capacitors from 1 kV to 150 kV: radial-lead ceramic discs, screw-terminal doorknob capacitors, metallized polypropylene film and safety-certified AC parts. Ceramic components use N4700 Class I or Y5T Class II dielectric and are screened to partial discharge ≤ 5 pC at rated voltage.

Choosing a high voltage capacitor starts with three questions: what voltage stands across it in service, how much capacitance the circuit needs, and how much capacitance drift the design can tolerate. Everything else — package, mounting, dielectric, termination — follows from those three. This page maps the families HVC makes onto those questions, then links to the detailed specification pages.

The three families at a glance

가족전압정전 용량유전체설치
Radial-lead ceramic disc1 kV – 50 kV catalogue, 70 kV to drawing10 pF – 33,000 pFN4700, Y5T, Y5P, Y5U, Y5V, SLRadial leads, 5–20 mm spacing
나사 단자형 도어 손잡이10kV – 150kV100 pF – 30,000 pFN4700, Y5T, Y5VM4 / M5 / 8-32 UNC stud
금속화 폴리프로필렌 필름700 – 3000Vdc0.0068~5.6 µFSelf-healing PP filmRadial, PCB mount
Safety certified AC250~760Vac100 pF – 1 µFY5P, Y5U, Y5VX1/Y1, X2/Y2 radial

High voltage resistors and rectifier diodes for the same circuits are on separate pages: thick film resistors 정류 다이오드.

Class I or Class II dielectric

This is the decision that most often goes wrong. Class I (N4700) holds its capacitance across temperature and voltage; Class II (Y5T, Y5P, Y5U, Y5V) packs more capacitance into the same body but drifts.

유전체클래스Drift over −30 to +85 °C제자리에
N4700클래스 IDefined negative coefficient, stableX-ray and CT tanks, laser PFN, snubbers, RF, HVDC valve positions
Y5P클래스 II± 10의 %General HV filtering, coupling
Y5T클래스 II+22% / -33%Cost-sensitive HV filtering and multipliers
Y5U / Y5V클래스 II+22% / −56% to −82%Non-critical decoupling where size dominates

If the circuit is a snubber, a pulse-forming network, a resonator or a voltage divider, drift changes the circuit behaviour and Class I is the only safe choice. If it is bulk filtering where a ±30% shift does not matter, Class II gives you the capacitance in a smaller body. The N4700과 Y5T 비교 숫자를 통해 계산합니다.

지원서를 통한 선발

어플리케이션일반적인 사양이곳에서 시작
Medical X-ray and CT high voltage tanks20–80 kV, N4700, PD ≤ 5 pC, oil immersed의료 영상 솔루션
Pulsed laser and PFN discharge10–50 kV, high dV/dt, low ESLPulsed power solutions
HVDC and VSC converter valves10–150 kV screw terminal, grading and snubber dutyHVDC valve capacitors
NDT and inspection X-ray30–100 kV, low ripple, stable capacitancePrecision inspection solutions
IGBT snubber and DC link700–3000 Vdc, self-healing film필름 콘덴서
AC line filtering and safetyX1/Y1, X2/Y2 rated to IEC 60384-14안전 콘덴서

Every voltage class, specified

Each rating below has its own specification page with the full part-number table, capacitance range, dielectric options, stud or lead dimensions. Use it to pick the exact value rather than browsing the catalogue.

전압Radial-lead ceramic disc나사 단자형 도어 손잡이
1kV – 8kV1 kV–8 kV disc specification-
10 kV10 kV disc specification-
15 kV15 kV disc specification-
20 kV20 kV disc specification20 kV doorknob specification
30 kV30 kV disc specification30 kV doorknob specification
40 kV40 kV disc specification40 kV doorknob specification
50 kV50 kV disc specification50 kV doorknob specification
70kV – 100kVDisc range to 50 kV; higher ratings built to drawing70–100 kV doorknob specification
150 kV-Screw-terminal, 800 pF, built to drawing — full doorknob range

Lead time by product family

가족일반적인 일정What confirms the date
Radial-lead ceramic discs일반적으로 3~4주Voltage, capacitance, dielectric, lead spacing, quantity and destination
Screw-terminal doorknob capacitorsFast catalogue ranges can be about 1 monthVoltage, capacitance, disc construction, stud, quantity and delivery location
Film and safety-certified AC capacitorsConfirmed by the selected seriesPart number, certification requirement, quantity and destination

These are normal planning ranges, not a promise of immediate stock. Custom voltage, capacitance, stud, insulation, coating, drawing or qualification requirements require a separate date confirmation after RFQ.

What the datasheet has to state

Four figures decide whether a high voltage capacitor survives. Ask for all four on any quotation, from any supplier:

Replacing a discontinued high voltage capacitor

Most of the high voltage capacitors in service today were designed in when a catalogue part existed. When Murata, TDK or Vishay ends a series, the board does not change — the capacitor has to fit the same footprint and mounting. HVC builds to the original drawing and publishes a cross-reference table with the offer. Send the original part number, the drawing or the datasheet page; the capacitor cross-reference index covers the Murata, TDK, Vishay and AVX programs already mapped.

자주하는 질문

What is the highest voltage available?

150 kV DC in screw-terminal ceramic. Above that, series stacks are built to drawing; the mechanical envelope becomes the limiting factor rather than the ceramic.

How much should I derate a high voltage capacitor?

For continuous DC duty, 50% to 70% of rated voltage is the working range most designs use. For repetitive pulse duty the limit is dV/dt and self-heating, not the DC rating — ask for the pulse data on the specific part.

Ceramic or film for a high voltage application?

Ceramic wins above roughly 10 kV and wherever the package must be small or the part must survive high temperature. Film wins where self-healing matters, where microfarads are needed, or where the pulse energy is large at a few kilovolts.

Do you supply single units and small lots?

Yes. Prototype and laboratory quantities are quoted the same way as production orders, with the partial-discharge record per unit.

리드 타임은 무엇입니까?

Standard ceramic ranges ship in 4 to 6 weeks; rectifier stacks and catalogue screw-terminal parts in 2 weeks. Quotations are returned within 6 hours.

Specifying a high voltage capacitor?

Send the working voltage, capacitance, dielectric class, package envelope and annual quantity. HVC replies with a matched part number, partial-discharge data and a 6-hour quotation.

기술 견적 요청 →