공학용 계산기

Voltage Coefficient (VCR) Error Calculator

빈R1(V)투표R20 VR0VRR(V)dR/R

도표를 읽는 방법. The top resistor changes value as the voltage across it rises, so the ratio at 20 kV is not the ratio you measured on the bench. The curve is that drift and dR/R is the error the calculator returns.

A thick film resistor is not the same value at 20 kV as on a bench meter. VCR is quoted in ppm per volt; this turns it into the resistance change and the divider error it causes.

입력

결과

R1 change
-
Ratio at 0 V
-
Ratio at working V
-
비율 오차
-
Output at working V
-

공식

ΔR/R = VCR × V / 1,000,000. Divider ratio = (R1 + R2) / R2; recalculate it with the shifted R1 to get the error.

계산기에 포함되지 않는 항목

부품 선택

Where the ratio matters, specify VCR explicitly: the 평면 후막 범위 is quoted for precision divider use, tolerance from 0.2%. For matched pairs, send the ratio and the voltage.